關于新國標消防應急燈相關問題討論://www.www69sihucomm.cn/
1.新(xin)《標(biao)(biao)準(zhun)》術語中(zhong)(zhong),明(ming)(ming)(ming)確地表達了“消防(fang)(fang)應(ying)(ying)急(ji)(ji)照(zhao)明(ming)(ming)(ming)燈(deng)(deng)(deng)”的(de)概(gai)念(nian)為(wei):包括(kuo)疏散照(zhao)明(ming)(ming)(ming)燈(deng)(deng)(deng)及(ji)消防(fang)(fang)工(gong)(gong)作照(zhao)明(ming)(ming)(ming)燈(deng)(deng)(deng);標(biao)(biao)志燈(deng)(deng)(deng)中(zhong)(zhong)除保留原內涵(han)外,增加(jia)了樓層、避難層指(zhi)示燈(deng)(deng)(deng),分類中(zhong)(zhong)增加(jia)了消防(fang)(fang)應(ying)(ying)急(ji)(ji)照(zhao)明(ming)(ming)(ming)(標(biao)(biao)志)燈(deng)(deng)(deng)具(ju)這(zhe)一復合(he)(he)形式(shi),內涵(han)的(de)擴展是(shi)為(wei)了今(jin)(jin)后(hou)工(gong)(gong)程設計中(zhong)(zhong)理我(wo)加(jia)明(ming)(ming)(ming)確消防(fang)(fang)應(ying)(ying)急(ji)(ji)燈(deng)(deng)(deng)使(shi)(shi)(shi)(shi)用(yong)場合(he)(he)及(ji)特點,便(bian)于今(jin)(jin)后(hou)設計規范的(de)制(zhi)定(ding);增加(jia)復合(he)(he)型式(shi)消防(fang)(fang)應(ying)(ying)急(ji)(ji)燈(deng)(deng)(deng)具(ju),是(shi)因實際產(chan)(chan)品中(zhong)(zhong)已具(ju)有該種型式(shi),但(dan)是(shi)以住實踐中(zhong)(zhong)部分工(gong)(gong)程設計、施工(gong)(gong)、使(shi)(shi)(shi)(shi)用(yong)人員(yuan)對此未有足(zu)夠(gou)(gou)認識(shi),實際上標(biao)(biao)志燈(deng)(deng)(deng)強調(diao)為(wei)表面亮(liang)度(du)顯示,對疏散照(zhao)并(bing)不作要求。例如(ru)電致發(fa)光屏類應(ying)(ying)急(ji)(ji)標(biao)(biao)志燈(deng)(deng)(deng)僅能(neng)符合(he)(he)標(biao)(biao)志燈(deng)(deng)(deng)要求但(dan)并(bing)無足(zu)夠(gou)(gou)亮(liang)度(du)產(chan)(chan)生(sheng);即使(shi)(shi)(shi)(shi)用(yong)采用(yong)熒光燈(deng)(deng)(deng)類應(ying)(ying)急(ji)(ji)標(biao)(biao)志燈(deng)(deng)(deng),如(ru)轉換亮(liang)度(du)低(di),亦(yi)僅能(neng)做為(wei)標(biao)(biao)志燈(deng)(deng)(deng)使(shi)(shi)(shi)(shi)用(yong)。只有既符合(he)(he)標(biao)(biao)志燈(deng)(deng)(deng)表面亮(liang)度(du)要求,又具(ju)有足(zu)夠(gou)(gou)的(de)轉換光通(tong),并(bing)能(neng)在結(jie)構上使(shi)(shi)(shi)(shi)地面產(chan)(chan)生(sheng)一定(ding)照(zhao)度(du)的(de)標(biao)(biao)志燈(deng)(deng)(deng)才能(neng)符合(he)(he)消防(fang)(fang)標(biao)(biao)志顯示及(ji)疏散照(zhao)明(ming)(ming)(ming)的(de)作用(yong),否則應(ying)(ying)另行裝設疏散照(zhao)明(ming)(ming)(ming)燈(deng)(deng)(deng)。
2.關于子母電源型(xing)(xing)、集中(zhong)控制型(xing)(xing)、集中(zhong)電源型(xing)(xing)、語(yu)言提(ti)示型(xing)(xing)、閃亮型(xing)(xing)及(ji)(ji)逐(zhu)次閃亮型(xing)(xing)消防應急(ji)燈具,均為(wei)原《標準(zhun)》中(zhong)沒有或只(zhi)是簡(jian)單提(ti)及(ji)(ji),但(dan)實際產品應用中(zhong)已存在,增加及(ji)(ji)補充這部分內容是十分必要的。
3.關于消(xiao)防(fang)標(biao)(biao)(biao)志燈表面標(biao)(biao)(biao)志住處的(de)顏(yan)色、亮(liang)(liang)(liang)(liang)(liang)度(du)(du)級別及亮(liang)(liang)(liang)(liang)(liang)度(du)(du)比(bi)等(deng)有關條(tiao)款,原(yuan)《標(biao)(biao)(biao)準》中(zhong)僅(jin)提到高(gao)(gao)、低(di)(di)亮(liang)(liang)(liang)(liang)(liang)度(du)(du)要求及高(gao)(gao)、低(di)(di)亮(liang)(liang)(liang)(liang)(liang)度(du)(du)比(bi)例,新標(biao)(biao)(biao)準中(zhong)考慮了(le)我(wo)國目前較(jiao)為流行的(de)電致發(fa)光應(ying)急標(biao)(biao)(biao)志燈均為這(zhe)類特型,并參考新標(biao)(biao)(biao)準版本,規定了(le)標(biao)(biao)(biao)志信(xin)息的(de)顏(yan)色組(zu)成,給定額中(zhong)不同(tong)型式的(de)標(biao)(biao)(biao)志燈表面亮(liang)(liang)(liang)(liang)(liang)度(du)(du)低(di)(di)及高(gao)(gao)限定以及本身的(de)亮(liang)(liang)(liang)(liang)(liang)度(du)(du)差;給定了(le)不同(tong)顏(yan)色交(jiao)界相鄰(lin)(lin)點(dian)的(de)亮(liang)(liang)(liang)(liang)(liang)度(du)(du)比(bi)。這(zhe)些規定均為保(bao)證標(biao)(biao)(biao)志燈在應(ying)用中(zhong)不因亮(liang)(liang)(liang)(liang)(liang)度(du)(du)過高(gao)(gao)和(he)相鄰(lin)(lin)反差太大(da)導致眩光產(chan)生;避免同(tong)種顏(yan)色相鄰(lin)(lin)顏(yan)色之(zhi)間(jian)亮(liang)(liang)(liang)(liang)(liang)度(du)(du)比(bi)太大(da)或大(da)小(xiao)而出現含(han)糊(hu)不清,影響視覺。
4.增加高(gao)危(wei)區域用消防應(ying)急(ji)燈,并確定其應(ying)急(ji)轉(zhuan)換時(shi)間(jian)為0.25S,是基于實(shi)際(ji)應(ying)用中有些場(chang)合,例(li)如高(gao)速運轉(zhuan)的(de)機床、商場(chang)中自動(dong)扶梯,在正常照(zhao)明切除后(hou),極易出(chu)現危(wei)險狀態。這(zhe)些場(chang)合應(ying)急(ji)轉(zhuan)換時(shi)間(jian)從5S縮短為0.25S,是符合實(shi)際(ji)情況需(xu)要(yao)的(de),同時(shi)亦與IEC有關標準(zhun)相吻合。高(gao)危(wei)場(chang)所用消防應(ying)急(ji)燈亦給(gei)工(gong)程(cheng)設(she)計(ji)人員在設(she)計(ji)類似場(chang)合的(de)應(ying)急(ji)照(zhao)明時(shi)提供必要(yao)的(de)產品標準(zhun)依據。
5.關于(yu)消防應急(ji)(ji)燈具應急(ji)(ji)低工(gong)(gong)作(zuo)時(shi)間(jian)從(cong)以前30min標準提高到45min,并增加分檔(dang)標稱工(gong)(gong)作(zuo)時(shi)間(jian),低工(gong)(gong)作(zuo)時(shi)間(jian)提高到45min,是(shi)綜合(he)(he)考(kao)慮(lv)我國高層(ceng)建(jian)筑(zhu)逐(zhu)漸增多,30min應急(ji)(ji)工(gong)(gong)作(zuo)時(shi)間(jian)余(yu)地(di)不(bu)夠(gou)(gou);同(tong)(tong)時(shi)亦考(kao)慮(lv)產品在使用過程中,因(yin)電老化導致應急(ji)(ji)工(gong)(gong)作(zuo)時(shi)間(jian)逐(zhu)漸下(xia)降,提高到45min可(ke)留下(xia)余(yu)地(di);增加分擋不(bu)同(tong)(tong)標稱應急(ji)(ji)工(gong)(gong)作(zuo)時(shi)間(jian),是(shi)為了便于(yu)今后設計(ji)規范的(de)制定。顯然,類似醫院、超(chao)高層(ceng)建(jian)筑(zhu)中不(bu)便于(yu)疏散場合(he)(he)、45min疏散時(shi)間(jian)可(ke)能不(bu)夠(gou)(gou),因(yin)此(ci)可(ke)在設計(ji)中定為90min或更長的(de)應急(ji)(ji)工(gong)(gong)作(zuo)時(shi)間(jian),以滿足(zu)實(shi)際需(xu)要。
6.關(guan)于各(ge)種狀(zhuang)態指示(shi)燈(deng),新(xin)《標準》中將原(yuan):”等(deng)候狀(zhuang)態”修正為“主電狀(zhuang)態”,其理(li)由是(shi)“等(deng)候狀(zhuang)態”易產(chan)生一些(xie)誤解(jie),在實(shi)際(ji)(ji)情況中,如消防應(ying)急燈(deng)即使未充(chong)足電,也可(ke)(ke)以是(shi)說已處(chu)于“的等(deng)候狀(zhuang)態”,主電中斷時亦可(ke)(ke)應(ying)急,只不過應(ying)急工作時間未達到標準要求而已;而且,采用:“等(deng)候狀(zhuang)態”,實(shi)際(ji)(ji)上與充(chong)電指示(shi)的實(shi)際(ji)(ji)意義雷(lei)同(tong)。因(yin)此,新(xin)標準中將其修正為“主電狀(zhuang)態”。
同時將“主電(dian)狀(zhuang)(zhuang)態(tai)”定(ding)為綠色(se),“充電(dian)狀(zhuang)(zhuang)態(tai)”定(ding)為紅色(se),故(gu)障狀(zhuang)(zhuang)態(tai)定(ding)為黃色(se),是考慮與(yu)其他(ta)消防設備的標(biao)(biao)準(zhun)(zhun)及參考上有關標(biao)(biao)準(zhun)(zhun)而確定(ding)。新《標(biao)(biao)準(zhun)(zhun)》中已明確指出(chu)了“故(gu)障狀(zhuang)(zhuang)態(tai)”內涵
7.關于異常(chang)(chang)電(dian)路狀(zhuang)態保(bao)護條(tiao)款,是(shi)參考上有(you)關同(tong)類標準(zhun)并結合實際情況(kuang)而制定。異常(chang)(chang)電(dian)路狀(zhuang)態保(bao)護是(shi)指非正常(chang)(chang)工作條(tiao)件(jian)下(xia),例如未裝光源,或使用(yong)過度(du)老(lao)化失(shi)效光源等(deng)等(deng),在主電(dian)及應急狀(zhuang)態下(xia),可能損壞或產生不(bu)因素。
8.關于(yu)熒光消防(fang)應(ying)(ying)急燈在(zai)應(ying)(ying)急狀態時不得(de)將(jiang)啟輝器接(jie)入(ru)應(ying)(ying)急回路(lu),是考慮(lv)到啟輝器的接(jie)入(ru)導致(zhi)應(ying)(ying)急轉換時間的不可靠性(xing),或(huo)導致(zhi)啟動失效。
廣(guang)大消費者業主(zhu),在新(xin)建項目中(zhong),購(gou)買(mai)新(xin)國(guo)(guo)標(biao)消防(fang)應急燈(deng)、指(zhi)示燈(deng),務必要(yao)拿到一(yi)對一(yi)的(de)檢(jian)測(ce)報(bao)告,務必購(gou)買(mai)正(zheng)規(gui)(gui)新(xin)國(guo)(guo)標(biao)消防(fang)應急燈(deng)廠家的(de)正(zheng)規(gui)(gui)產品,以防(fang)不(bu)能通過(guo)消防(fang)檢(jian)查。